Selected language Deutsch Deutsch
Change language
Change language page on English EnglishChange language page on Español EspañolChange language page on Français FrançaisChange language page on Italiano ItalianoChange language page on Polski PolskiChange language page on Türkiye Türkiye ČeskyChange website to USA USAChange language page on 中文 中文

Präzisionswaage PS 1200.R2

Präzisionswaage PS 1200.R2 - RADWAG Elektronische Waagen
This image is for reference only.

Produktcode: WL-212-0023
Kontaktformular

Beschreibung

Wägebereich [Max]: 1200g
Ziffernschritt [d]: 0,01g


PS.R2 series

balances

represent a new standard of precision balances. They feature a new, readable LCD display which allows a clearer presentation of the

weighing

result. Besides, the display has a new text information line allowing to show additional messages and data, e.g. product name or tare value. 
New PS.R2 balances, like previously designed PS series balances, have pans in two possible dimensions: 128x128 mm or 195x195 mm.

balances

with a smaller pan have a draft shield. The

balance

precision and the measurement accuracy is assured by automatic internal adjustment, which takes into consideration temperature changes and time flow.
PS.R2 balances feature several communication interfaces: 2 x RS 232, type A USB, type B USB and optional Wireless Connection.

The

balance

may cooperate with computer by means of USB interface supposing a supplementary software has been installed (respective driver). The said driver may be downloaded from RADWAG website – SOFTWARE link or SUPPORT section.


The housing is made of plastic, and the pan is made of stainless steel.
The balances have a possibility to weigh products out of the pan (under-pan weighing) - the load hangs under the pan. 
 
DATABASES IN R SERIES BALANCES
 
The information system is based on 5 databases, which allows for several users to work with several products databases, and the registered

weighing

results can be subject to further analysis.

The data is registered in 5 databases:
  • users (up to 10 users),
  • products (up to 1000 products),
  • weighments

    (up to 5000 weighments),
  • tares (up to 100 tares),
  • ALIBI memory (up to 100 000 weighments).
There is two directions data exchange within the system thanks to a quick USB interface. New balances allow to import and export databases using USB pen drives.

Quick access to information
 
Direct access to functions and databases is possible from the level of keyboard. 
 
Database – a direct access to databasis
Function - a direct access to the basic functions
F1 to F4 – programmable function and navigation keys on the menu

ALIBI memory
 
The used ALIBI memory is a data secure area  and allows to record up to 100 000 weighment records.  It ensures security of constant data register in the long time period.

Videos

R Series Laboratory Balances

Merkmale

Schnittstellen
Schnittstellen:
- 2×RS 232
- USB-A
- USB-B
- Wi-Fi®® (optional)

Schnittstellen

Schnittstellen:
- 2×RS 232
- USB-A
- USB-B
- Wi-Fi®® (optional)
Zusätzliche Funktionsschaltflächen
Die Waage ist mit 2 Funktionsschaltflächen und 4 programmierbaren Funktionstasten ausgestattet.
Die 2 Funktionsschaltflächen dienen zum Öffnen der Datenbank sowie der Funktionen. Außerdem stehen zur Verfügung 4 programmierbare Funktionstasten F1-F4.
In jeder Betriebsart können die nachfolgenden Funktionen ausgeführt werden:
- Kopfzeile drucken,
- Tara bearbeiten,
- Fußzeile drucken,
- Auswahl Produkt.

Zusätzliche Funktionsschaltflächen

Die Waage ist mit 2 Funktionsschaltflächen und 4 programmierbaren Funktionstasten ausgestattet.
Die 2 Funktionsschaltflächen dienen zum Öffnen der Datenbank sowie der Funktionen. Außerdem stehen zur Verfügung 4 programmierbare Funktionstasten F1-F4.
In jeder Betriebsart können die nachfolgenden Funktionen ausgeführt werden:
- Kopfzeile drucken,
- Tara bearbeiten,
- Fußzeile drucken,
- Auswahl Produkt.
Zusätzliche Informationszeile
In der Informationszeile werden Informationen über den Wägevorgang wie z.B. die Bezeichnung des Produktes, der Tarawert, der Name des Bedieners etc. angezeigt.
In der Informationszeile werden Informationen über den Wägevorgang wie z.B. die Bezeichnung des Produktes, der Tarawert, der Name des Bedieners etc. angezeigt.
Eine Neuheit ist ein Paket mit Piktogrammen zur Anzeige der gewählten Betriebsart, der Verbindung mit PC, des Akkustandes, der Wäge- oder Servicefunktionen.

Zusätzliche Informationszeile

In der Informationszeile werden Informationen über den Wägevorgang wie z.B. die Bezeichnung des Produktes, der Tarawert, der Name des Bedieners etc. angezeigt.
In der Informationszeile werden Informationen über den Wägevorgang wie z.B. die Bezeichnung des Produktes, der Tarawert, der Name des Bedieners etc. angezeigt.
Eine Neuheit ist ein Paket mit Piktogrammen zur Anzeige der gewählten Betriebsart, der Verbindung mit PC, des Akkustandes, der Wäge- oder Servicefunktionen.

Funktionen

Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Totalizing

Totalizing

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Peak hold

Peak hold

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.
Newton unit measurement

Newton unit measurement

Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
Under-pan weighing

Under-pan weighing

The solution enables weighing with use of a stand, which is advisable for loads of non-standard shapes and dimensions and those that generate magnetic field.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Density determination

Density determination

Liquid or solid body density function uses the Archimedes principle and it requires a special kit to be applied. The kit when used, replaces a weighing pan. For solids mass of the sample must be determined first in the air, next in the liquid of specified density. For liquids the so called sinker, density of which has been determined, must be measured first in the air, next in the tested liquid. The density determination process is disturbed by air bubbles which may stick either to the measured sample or the sinker. In case of laboratory equipment very light solids may be measured. For industry, solid bodies density may be determined by means of  under-pan weighing. Tested load of significant size may be measured this way.

Technische Daten

Wägebereich [Max]

1200

 g

Min. Belastung

500

 mg

Ziffernschritt [d]

0,01

 g

Tarierbereich

-1200

 g

Wiederholbarkeit (5% Max)

0,005

 g

Wiederholbarkeit (Max)

0,01

 g

Linearität

±0,02

 g

Stabilisierungszeit

1,5

 s

Justierung

intern (automatisch)

 

Display

LCD (hinterleuchtet)

 

Schnittstelle

2×RS232, USB-A, USB-B, Wi-Fi® (optional)

 

Stromversorgung

100 ÷ 240 V AC 50 / 60 Hz

 

Umgebungstemperatur

+10 ÷ +40

 °C

Waagschale

195×195

 mm

Verpackungsgröße

470×380×336

 mm

Nettogewicht

4,3

 kg

Bruttogewicht

5,8

 kg

Dokumentation

Technische Dokumentation
Publikationen und Lerninhalte

Bedienungsanleitungen
(2.53 MB)

Save
See the publication

Produktfolder
(1.35 MB)

Save
See the publication

Conformity Declaration
(0.04 MB) EN

Save
See the publication

Defined Weighing Profiles
(1.64 MB) EN

Save
See the publication

Direkte Kommunikation Waage-PC
(0.32 MB)

Save
See the publication

R Laborwaagen
(1.74 MB)

Save
See the publication

Waagen Serie R
(2.13 MB)

Save
See the publication

Alibi Reader - tutorial
(1.47 MB) EN

Save
See the publication

Zubehör

ALIBI Reader
E2R System
R Panel

Zubehör

Produktname

Beschreibung

R Panel

...

R.Barcode

Zubehör

Produktname

Beschreibung

R.Barcode

R-LAB
RAD KEY
RADWAG Development Studio
LabVIEW Driver
Gestell für Unterflurwägen

Zubehör

Dichtebestimmungsset
Thermische Drucker
Kabel RS 232 (Waage – Drucker EPSON)
Kabel RS 232RS 485
USB-Kabel (Waage – Drucker)
Anschlusskabel für Zigarettenanzünder
Schutzhauben
Barcodescanner
Waagenkoffer
Ausgänge der Stromschnittstelle
Displays
Netzteile

RADWAG Elektronische Waagen

Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag
© 2019 RADWAG Elektronische Waagen. Alle Rechte vorbehalten.

See our movies
RADWAG