Analysenwaage XA 110.4Y.F - Schnellere Messungen mit neuem CPU Die 4Y Waagen sind mit einem Dual-Core-Prozessor 2×1 GHz ausgestattet, der für eine kürzere Stabilisierungszeit des Ergebnisses bei einer entsprechenden Wiederholbarkeit sorgt. 16 GB Speicher - neue Möglichkeiten der Datenverwaltung Die Erweiterung des Waagenspeichers auf 16 GB ermöglicht das Schreiben der Daten in Form von ausführlichen Protokollen sowie Zeitdiagrammen und statistischen Diagrammen von Wägeserien
This image is for reference only.

Produktcode: WL-107-0089
Kontaktformular

Beschreibung

Wägebereich [Max]: 110g
Ziffernschritt [d]: 0,01mg


Schnellere Messungen mit neuem CPU
Die 4Y

Waagen

sind mit einem Dual-Core-Prozessor 2×1 GHz ausgestattet, der für eine kürzere Stabilisierungszeit des Ergebnisses bei einer entsprechenden Wiederholbarkeit sorgt.

16 GB Speicher - neue Möglichkeiten der Datenverwaltung
Die Erweiterung des Waagenspeichers auf 16 GB ermöglicht das Schreiben der Daten in Form von ausführlichen Protokollen sowie Zeitdiagrammen und statistischen Diagrammen von Wägeserien.

Höchste Wiederholbarkeit und USP-Konformität
Höchste Wägepräzision und Wiederholbarkeit sd ≤ 1d sowie die USP-Konformität (Kapitel 41 und 1251) machen die 4Y

Waage

zum neuen Maßstab im Bereich der Qualität der Massemessungen.

Ergonomie und Betriebssicherheit
Die drahtlose Kommunikation zwischen dem Wägeterminal und der Messeinheit ermöglicht das Betreiben der 4Y

Waagen

auf Sicherheitswerkbänken und unter Abzügen.

Mobilität
Das Standard Wireless Connection ermöglicht den Datentransfer von 4Y Waagen an mobile Geräte mit iOS- und Android-Systemen mit speziellen Apps zum Datenmanagement.

Datensicherheit
Alle Waagen der Serie 4Y sind mit dem ALIBI-Speicher ausgestattet, der für die Sicherheit und die automatische Erfassung der Messungen sorgt, sowie die Einsicht, das Kopieren und die Archivieren der Daten ermöglicht.

Videos

RADWAG Remote Desktop - Windows 10
RADWAG Remote Desktop
4Y Balances: Video-Guidance and an on-screen manuals
4Y Series RADWAG Balances

Merkmale

Elektronische Libelle
Funktionalität:
  • ALARM
  • graphische Nivellierungsanzeige
  • programmierbare Toleranzen

Elektronische Libelle

Funktionalität:
  • ALARM
  • graphische Nivellierungsanzeige
  • programmierbare Toleranzen
Datenaustausch (USB)
  • Softwareupdates
  • Export von Wägedaten
  • Export/Import von Datenbanken
  • Export/Import von Waageneinstellungen
  • Datenaustausch zwischen Waagen

Datenaustausch (USB)

  • Softwareupdates
  • Export von Wägedaten
  • Export/Import von Datenbanken
  • Export/Import von Waageneinstellungen
  • Datenaustausch zwischen Waagen
Infrarotsensoren
Funktionalität:
  • PRINT-Funktion
  • TARA-Funktion

Infrarotsensoren

Funktionalität:
  • PRINT-Funktion
  • TARA-Funktion
Interfaces
  • Ethernet
  • 2×USB
  • 2×RS 232
  • 4 in / 4 out
  • WiFi 2,4GHz b,g,n

Interfaces

  • Ethernet
  • 2×USB
  • 2×RS 232
  • 4 in / 4 out
  • WiFi 2,4GHz b,g,n

Funktionen

Autotest

Autotest

Diagnostic function aiming at metrological parameters determination (repeatability), the parameters are determined for the actual conditions of use. When speaking of repeatability it may be also used for weighing time optimization. Autotest is operated in an automatic mode thus operator’s time is saved.
Dosing

Dosing

Weighing process for which reference mass has been determined together with tolerance for its determination. Dosing tolerance is given in [%] and it is calculated in relation to the reference value thus being a permissible deviation of this process. This solution is used for weighing powders, liquids and loose materials. Dosing function performance is often supported with bargraph - load indicator. For industrial scales it is possible to use a control systems of dosing process.
Percent Weighing

Percent Weighing

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.
Parts counting

Parts counting

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supperted by a mechanism of Automatic Correction of Accuracy. This allows to update single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with checkweighing and dosing thus industry solutions feature audio signalling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platfroms of different MAX capacities and different accuracies.
Formulation

Formulation

Function supporting the mixture making process, wherein the mixture contains various components. Formulation function usually uses the balance/scale database of components. Formulation serves for monitored checkweighing of every single component with a given tolerance. It is enriched with a set of individual settings.
Statistics

Statistics

Statistiscs function registers and analyses performed measurements. This supplies the user withthe following information: Max and Min standard deviation, average value, variance, range et.
Checkweighing

Checkweighing

Checkweighing function is used for checking whether the measured sample mass is within the predefined threshold values, Low [LO] and Hgh [HI]. The thresholds are given in [g] and [kg] units. Current state of a sample being measured is signalled by means of pictorgams located on a display for laboratory balances, for industrial scales Stackligt System is used. This visual +/- inspection is in operation during segregation, control or packing process of products for which mass has bees determined with a specifaied tolerance, eg. 12860 g 961
IR sensors

IR sensors

Programmable function supporting the weighing process through control of the following options: sliding weighing chamber doors, printout, zeroing, tarring etc. Especially appreciated wherever preventing the balance from soiling is important.
GLP Procedures

GLP Procedures

Diagnostic function allowing to objectively document performed measurements. GLP procedures may be either presented in a short report form or extended one.
Animal weighing

Animal weighing

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimize the function depending on the measured product characteristics.
Pipettes Calibration

Pipettes Calibration

Function verifying correctness of piston pipettes functioning, the verification is performed via gravimetric measurement of the excreted liquid. Pipettes calibration may be either a stand-alone module or it may be operated
Air density correction

Air density correction

Function performing correction of mass measurement indication, wherein the air density is taken into account. It is used in balances with reading unit < 0,01 mg.
Differential weighing

Differential weighing

Differential weighing informs about mass variation a particular sample, wherein the said variation is a result of manufacturing processes.

Differential weighing is often applied in product control process, for which reference product parameters have been specified in order to be used as a source of comparison for the whole series.
Insuchcasestandard deviation is the information which tells about quality and completeness of a final product. For systems based on a feed-back technique such information may be used by control units.
Replaceable unit

Replaceable unit

Replaceable units.
Statistical Quality Control

Statistical Quality Control

Statistical control for determination of basic statistical criteria: maximum, minimum, standard deviation, mean values for each batch, etc.
ALIBI Memory

ALIBI Memory

"ALIBI" memory enables saving and storing up to 100000 measurements.  Measurements are saved automatically upon each pressing of the key. There is no need for any additional operations or changing settings.
The following data related with the measurements is saved: measurement date; measurement time; result (mass); tare value; operator carrying out the measurement (logged in); product name.
The software saves the measurement in a so called loop, i.e. when the measurement no. 100001 is saved, the measurement 1 gets automatically deleted from the memory.
Measurements saved to balance memory cannot be deleted.
You can preview and print out the data saved to the ALIBI database.

Technische Daten

Wägebereich [Max]

110

 g

Min. Belastung

1

 mg

Ziffernschritt [d]

0,01

 mg

Tarierbereich

-110

 mg

Wiederholbarkeit (Max)

0,02

 mg

Wiederholbarkeit (5% Max)

0,007

 mg

Linearität

±0,06

 mg

Exzentrizität

0,06

 mg

Min. Einwaage

1,4

 mg

Min. Einwaage USP

14

 mg

Stabilisierungszeit

5 s (30 s für die Filter)

 

Justierung

intern (automatisch)

 

OIML-Klasse

I

 

Display

5,7” resistiv farbiger touchscreen

 

Schnittstelle

2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®

 

Stromversorgung

100 ÷ 240 V AC 50 / 60 Hz

 

Umgebungstemperatur

+10 ÷ +50

 °C

Waagschale

210×254 mm für die Filter + ø90 mm spezielle Waagschale + ø85 mm volle Waagschale (optional)

 

Verpackungsgröße

870×510×685

 mm

Nettogewicht

12,7

 kg

Bruttogewicht

25

 kg

Wiederholbarkeit wird als Standardabweichung von 10 Wägezyklen ausgedrückt.
Die Stabilisierungszeit ist abhängig von den Umgebungsbedingungen und der Geschwindigkeit bei Auflegen der Last auf der Waagschale; für FAST-Profil definiert.

Dokumentation

Technische Dokumentation
Publikationen und Lerninhalte
Bedienungsanleitungen
(5.49 MB)
Save See the publication
Data Sheet
(0.18 MB) EN
Save See the publication
Produktfolder
(1.50 MB)
Save See the publication
Conformity Declaration
(0.04 MB) EN
Save See the publication
Defined Weighing Profiles
(1.36 MB) EN
Save See the publication
THBR System 2.0
(5.17 MB) EN
Save See the publication
Detection of vibrations at the electronic balances workstation
(2.02 MB) EN
Save See the publication
4Y - Neue Serie Der Laborwaagen
(1.76 MB)
Save See the publication
Waagen der Serie 4Y
(2.35 MB)
Save See the publication
Micro Scale Measurement
(2.74 MB) EN
Save See the publication
Principles_of_metrology
(0.10 MB) EN
Save See the publication
SQC in laboratory
(2.31 MB) EN
Save See the publication

Zubehör

Granit-Antivibrationstisch
Antivibrationstische für Laborwaagen
Professioneller Wägetisch
Audit Trail Reader

Zubehör

E2R System
Etiketten Editor R02
Parametereditor
R.Barcode

Zubehör

Produktname

Beschreibung

R.Barcode

R-LAB
RAD KEY
RADWAG Development Studio
RADWAG Remote Desktop
LabVIEW Driver
Gestell für Unterflurwägen

Zubehör

Produktname

Beschreibung

Podest für Unterflurwägung XA

...

Dichtebestimmungsset
Thermische Drucker
Etikettendrucker
Umgebungsbedingungen-Messgeräte THBR 2.0 System

Zubehör

Produktname

Beschreibung

Modul THB P

...

Modul THB S

...

Kabel RS 232RS 485
Kabel RS 232 (Waage – Drucker EPSON)
Barcodescanner
Halter für Reagenzgläser und Filter
Displays
Netzteile

Zusätzliche Module

Modul der Konformität mit 21 CFR Teil 113

RADWAG Elektronische Waagen

Torunska 5
26-600 Radom
Polen
Tel.: +48 48 386 60 00
E-mail: export@radwag.com
VAT Nr.: 796-000-03-27
Vimeo Radwag YouTube Radwag Facebook Radwag